The following suppliers offer Büchi Labortechnik products. Use the overview to compare suitable suppliers, product categories and laboratory products and send a direct request.
Send your request to selected suppliers at the same time. They will contact you without obligation with suitable proposals.
Product categories linked on LabFinder with further independent product knowledge.
Flash chromatography rapidly purifies and isolates liquid mixtures through adsorption-based separation on low-pressure columns. It is used for organic, synthetic, and biological samples in preparative or analytical workflows. Select columns, adsorbents, solvents, pressure range, and UV-VIS detection according to sample volume, resolution, and analyte solubility.
View product category →Infrared digestion systems support rapid chemical sample digestion for Kjeldahl nitrogen determination, TOC analysis in water and wastewater, and other high-temperature procedures. Direct infrared irradiation promotes fast, even heating. Select systems by sample composition, required temperature range, volume, throughput, automation, vessel type, and procedure compatibility.
View product category →Extraction systems selectively separate substances from complex solid or liquid mixtures using solvents, supporting the isolation and concentration of plant extracts, essential oils, and active ingredients. Choose according to sample type, solvent compatibility, extraction method, automation, volume, throughput, and solvent-handling safety requirements.
View product category →Lyophilizers freeze-dry sensitive, thermolabile samples by sublimating ice under vacuum, minimizing heat exposure and supporting long-term storage stability. Selection should consider drying-chamber size and design, vacuum level, cooling performance, freezing and drying temperature ranges, and automation needs.
View product category →Rotary evaporators gently remove, concentrate, or dry solvents under reduced pressure, using rotation to create a large evaporation surface for rapid low-temperature processing. Consider flask capacity, heating bath type, temperature and speed ranges, vacuum control, and condenser configuration; they are less suitable for highly viscous or low-volatility samples.
View product category →Spray dryers convert solutions, suspensions, and emulsions into dry powders by atomizing them into fine droplets that evaporate in a warm gas stream. They support rapid, homogeneous drying of sensitive substances. Selection depends on sample properties, drying requirements, temperature resistance, desired particle size, atomization method, throughput, and cleaning needs.
View product category →Infrared digestion systems support rapid chemical sample digestion for Kjeldahl nitrogen determination, TOC analysis in water and wastewater, and other high-temperature procedures. Direct infrared irradiation promotes fast, even heating. Select systems by sample composition, required temperature range, volume, throughput, automation, vessel type, and procedure compatibility.
View product category →Laboratory evaporators reduce liquid sample volume by removing solvent, helping concentrate solutions and simplify sample preparation. Choose according to solvent type and volume, sample properties, required evaporation parameters, and safety needs for volatile or flammable solvents. Rotary, vacuum, and ultrasonic designs support different evaporation approaches.
View product category →Extraction systems selectively separate substances from complex solid or liquid mixtures using solvents, supporting the isolation and concentration of plant extracts, essential oils, and active ingredients. Choose according to sample type, solvent compatibility, extraction method, automation, volume, throughput, and solvent-handling safety requirements.
View product category →Lyophilizers freeze-dry sensitive, thermolabile samples by sublimating ice under vacuum, minimizing heat exposure and supporting long-term storage stability. Selection should consider drying-chamber size and design, vacuum level, cooling performance, freezing and drying temperature ranges, and automation needs.
View product category →Rotary evaporators gently remove, concentrate, or dry solvents under reduced pressure, using rotation to create a large evaporation surface for rapid low-temperature processing. Consider flask capacity, heating bath type, temperature and speed ranges, vacuum control, and condenser configuration; they are less suitable for highly viscous or low-volatility samples.
View product category →Spray dryers convert solutions, suspensions, and emulsions into dry powders by atomizing them into fine droplets that evaporate in a warm gas stream. They support rapid, homogeneous drying of sensitive substances. Selection depends on sample properties, drying requirements, temperature resistance, desired particle size, atomization method, throughput, and cleaning needs.
View product category →Flash chromatography rapidly purifies and isolates liquid mixtures through adsorption-based separation on low-pressure columns. It is used for organic, synthetic, and biological samples in preparative or analytical workflows. Select columns, adsorbents, solvents, pressure range, and UV-VIS detection according to sample volume, resolution, and analyte solubility.
View product category →Medium-pressure liquid chromatography separates complex mixtures, including crude oils and plant extracts, into distinct fractions through silica-based column chromatography. Choose systems based on pressure range, column type, mobile-phase compatibility, flow rate, detection, and control requirements. MPLC is less suited to very small molecules or high-resolution analysis.
View product category →Preparative chromatography enables targeted separation and purification from milligram to kilogram scale for research, development, and production. Select methods such as flash chromatography, preparative HPLC, or FPLC according to substance type, sample quantity, and required purity. Separation can use adsorption, ion exchange, or size exclusion.
View product category →Chillers remove heat from liquid coolants and circulate the cooled liquid through heat exchangers to maintain defined temperatures in laboratory and process applications. Selection depends on cooling load, required temperature, refrigerant and process-media compatibility, connections, and whether vapor-compression, adsorption, or absorption operation is suitable.
View product category →Freeze dryers gently preserve thermosensitive samples by removing water through sublimation from frozen to gaseous state, helping retain structure and activity. Used in pharmaceutical research, biotechnology, food analysis, and molecular biology, they can be selected by capacity, vacuum quality, cooling performance, and process-control capabilities.
View product category →Laboratory vacuum pumps generate controlled negative pressure for filtration, distillation, drying, and evacuation. Select by required vacuum level, pumping speed, operating principle, and compatibility with process media. For very low pressures, specialized pumps or backing-pump combinations may be required.
View product category →Vacuum regulators control, measure and monitor vacuum processes, helping maintain defined pressure values and protect sensitive steps from fluctuations. Choose according to required accuracy, chemical resistance, system compatibility and control range; mechanical designs use bellows or diaphragms, while electronic models use sensors.
View product category →Kjeldahl systems determine total nitrogen in nitrogen-containing samples through acidic digestion, ammonia release by distillation, and subsequent quantification. They support chemistry, environmental, food, and occasional clinical testing. Choose manual to fully automated formats based on sample capacity, throughput, sample compatibility, accuracy, reproducibility, and cleaning requirements.
View product category →Laboratory dryers remove moisture from samples and materials for analytical preparation, storage, or conditioning, supporting stability and reproducible results. Select by material type, temperature, and drying time: hot air evaporates moisture, while vacuum drying lowers evaporation temperature for sensitive samples.
View product category →All 15 product categories
Do you offer products from Büchi Labortechnik? Present your company on LabFinder and gain visibility for this brand, suitable product categories and enquiries.